Specifications :
General :
- Compatible readers : All current BioTek microplate readers
- Validation guidelines : Validated per US FDA and ISO 9001/ISO 13485 requirements
- Software validation package : Available
- Operating system : Microsoft® Windows® 7 32 and 64 bits, Windows Vista and Windows XP (Pro editions)
- Minimum requirements : Pentium® III 500 MHz, 512 MB RAM, 2 GB hard drive space
- Plate geometries : >80 pre-programmed, user programmable
Reader Control :
- Simultaneous control: 2 readers
- Pathlength correction : On select readers
- Steps per sequence : Unlimited
- Detection modes per sequence : Unlimited
- Multi-mode kinetic : Up to 3 detection modes per kinetic loop
- Area scan resolution : Up to 99 x 99 (9,800 data points per well) on select readers
- Shaking duration : 16-minutes stand-alone step; Unlimited continuous shaking in kinetic cycles
Data Analysis :
- Protocol type :
- Standard (plates are independent)
- Calibrator (1 calibration plate, multiple sample plates)
- Multi-Plate (standard and controls on several plates)
- Paneled (multiple assays per plate)
- Sample types : Standards, assay controls, sample controls (spikes), blanks, samples
- Transformation steps: Unlimited
- Basic transformations: Blanking, ratio, delta, normalization, custom
- Curve fits: Linear, polynomial (degree 2 to 6), 4-P, 5-P, Logit-Log, Point to Point, Spline
- Weighting: 1/Y, 1/Y2, 1/(Std dev Y2,) 1/S2
- Parameter constraint: Estimate all, Y intercept, fixed parameters
- Parallel line analysis: Standard, non linear analysis for relative potency calculation
- Dose-response: EC50/IC50 calculation
- Kinetic analysis: Max slope, mean slope, min/max signal, lag time, Y intercept, onset time, area under the curve, custom
- Spectral analysis: Min/max signal, peak wavelength, integral, custom
- Qualitative analysis: Multi-cutoff data analysis
Validation and QC :
- QC trending: Levey-Jennings charts (Gen5 Secure)
- Pass/fail validation criteria: Yes
- Z’ analysis: Yes
- Statistics (mean, stdev, %CV): Yes, automatically calculated on replicates
Exporting :
- Format : .xls, .xlsx, .xlsm, .csv, .txt
- Quick export : One click any data / graph on screen
- PowerExport : Auto / customizable embedded Microsoft Excel spreadsheet
- ASCII export : Auto / customizable text export
- Number of exports per file : Unlimited
Reporting :
- Number of reports per file : Unlimited
- Report type :
- Per plate: All data regrouped per microplate
- Per sample : All data regrouped per sample
Gen5 Secur e - 21 CFR Part 11 Compliance :
- System administrator: Creation and maintenance of user accounts and user groups
- Protected functions: Per user account
- Time-stamped audit trails: Data and protocol audit trails
- Electronic signatures: Data and protocols
- Secure record storage: Gen5 files stored in secure shared-access database
- Windows authentication: Single Sign On (SSO) available
- Email notification: Automatic email notification based on trigger event
*Specifications subject to change