Lustiner
Panier d'achat
Votre panier est vide

Logiciel complet "Gen5 Version 2.0 Data Analysis Solftware" pour lecteur ELx800 BioTek®

A valider à la commande du lecteur ELx800 BioTek®, pour paramétrage.

Référence : 7476748

Unité de vente : Pièce

1216.33 €HT

 Ajouter au panier

Specifications :

General :
- Compatible readers : All current BioTek microplate readers
- Validation guidelines : Validated per US FDA and ISO 9001/ISO 13485 requirements
- Software validation package : Available
- Operating system : Microsoft® Windows® 7 32 and 64 bits, Windows Vista and Windows XP (Pro editions)
- Minimum requirements : Pentium® III 500 MHz, 512 MB RAM, 2 GB hard drive space
- Plate geometries : >80 pre-programmed, user programmable

Reader Control :
- Simultaneous control: 2 readers
- Pathlength correction : On select readers
- Steps per sequence : Unlimited
- Detection modes per sequence : Unlimited
- Multi-mode kinetic : Up to 3 detection modes per kinetic loop
- Area scan resolution : Up to 99 x 99 (9,800 data points per well) on select readers
- Shaking duration : 16-minutes stand-alone step; Unlimited continuous shaking in kinetic cycles

Data Analysis :
- Protocol type :
  - Standard (plates are independent)
  - Calibrator (1 calibration plate, multiple sample plates)
  - Multi-Plate (standard and controls on several plates)
  - Paneled (multiple assays per plate)
- Sample types : Standards, assay controls, sample controls (spikes), blanks, samples
- Transformation steps: Unlimited
- Basic transformations: Blanking, ratio, delta, normalization, custom
- Curve fits: Linear, polynomial (degree 2 to 6), 4-P, 5-P, Logit-Log, Point to Point, Spline
- Weighting: 1/Y, 1/Y2, 1/(Std dev Y2,) 1/S2
- Parameter constraint: Estimate all, Y intercept, fixed parameters
- Parallel line analysis: Standard, non linear analysis for relative potency calculation
- Dose-response: EC50/IC50 calculation
- Kinetic analysis: Max slope, mean slope, min/max signal, lag time, Y intercept, onset time, area under the curve, custom
- Spectral analysis: Min/max signal, peak wavelength, integral, custom
- Qualitative analysis: Multi-cutoff data analysis

Validation and QC :
- QC trending: Levey-Jennings charts (Gen5 Secure)
- Pass/fail validation criteria: Yes
- Z’ analysis: Yes
- Statistics (mean, stdev, %CV): Yes, automatically calculated on replicates

Exporting :
- Format : .xls, .xlsx, .xlsm, .csv, .txt
- Quick export : One click any data / graph on screen
- PowerExport : Auto / customizable embedded Microsoft Excel spreadsheet
- ASCII export : Auto / customizable text export
- Number of exports per file : Unlimited

Reporting :
- Number of reports per file : Unlimited
- Report type :
  - Per plate: All data regrouped per microplate
  - Per sample : All data regrouped per sample

Gen5 Secur e - 21 CFR Part 11 Compliance :
- System administrator: Creation and maintenance of user accounts and user groups
- Protected functions: Per user account
- Time-stamped audit trails: Data and protocol audit trails
- Electronic signatures: Data and protocols
- Secure record storage: Gen5 files stored in secure shared-access database
- Windows authentication: Single Sign On (SSO) available
- Email notification: Automatic email notification based on trigger event

*Specifications subject to change

Poids 0,2 Kg   (200 g)
Volume 0,0001 m³   (100 cm³)
Largeur 0,001 m   (0,1 cm)
Longueur 0,001 m   (0,1 cm)
Hauteur 0,001 m   (0,1 cm)
Les dimensions, le poids et le volume sont bruts (emballage inclus)

Articles requis

Lecteur de microplaques [400-750 nm, par filtres] - 0 à 3 OD - BP=10 nm ELx800 BioTek®
Plaques: 6 à 96 cupules. Cap.: 5 filtres interférentiels dont 405, 450, 490, 630 nm livrés
Référence : 4674130, Unité de vente : Pièce
4842.96 € Ajouter au panier
Portail collaboratif Réalisé par Ovidentia, Ovidentia est une marque déposée par Cantico. Gestion